Lower is not always better for a dry cabinet, and neither is higher: too low wastes power and can over-dry items; too high fails to protect. NABOXSUN cabinets adjust freely from 20–98%RH with ±3%RH precision, show current temperature and humidity on the LCD, and hold the set value automatically.
Lower is not always better for a dry cabinet, and neither is higher: too low wastes power and can over-dry items; too high fails to protect. Different items need different levels — the table below is the reference for common products.
| Item | Recommended humidity |
|---|---|
| Antiques, paper money, fax paper | 55–60%RH |
| Cameras, lenses, filters, computer products, slides, tapes, CD-ROMs, PDAs, microphones | 45–55%RH |
| Photoelectric semiconductors, electronic parts, semi-finished goods | 40%RH 以下 |
| Precision metal products, silver and copper ware, model cars, cutters, measuring tools, instruments | 40–50%RH |
| Medicines, health foods, herbs, dry foods | 30–40%RH |
| Chemical raw materials, seeds, pollen, dried flowers | 30%RH 以下 |
NABOXSUN cabinets adjust freely from 20–98%RH: set the value on the panel and the LCD shows the set value and the current temperature and humidity directly. Once the set value is reached, the microcomputer holds it steady automatically, restarting only when humidity exceeds the setpoint by 3%RH; the setting survives a power cut.
Semiconductor-chip dehumidification is 8× faster than physical adsorption: a 70L cabinet drops from 70%RH to 40%RH in about 2–3 hours, versus about 24 hours for physical adsorption. Larger cabinets and higher starting humidity take longer.
Humidity readings depend on where they are measured: readings differ between positions inside the cabinet, so place the test instrument at the same position as the sensor; recalibrate the instrument at least once a year.
In short: pick the level from the table above, check the current humidity on the LCD, fine-tune if needed — then the microcomputer holds it steady with no daily attention.
Pick by item type: electronic components below 40%RH, photo gear and optical instruments 45–55%RH, precision metal products 40–50%RH. Range is 20–98%RH with ±3%RH precision.
The microcomputer detects humidity changes and adjusts automatically until the set value is reached and held; the LCD shows current temperature and humidity directly. A 70L cabinet drops from 70%RH to 40%RH in about 2–3 hours.
When seasons change, check the current temperature and humidity on the LCD and fine-tune the setting if needed.